jainsonsindia partners
 Enquiry Cart

RTD STUDIES IN PACKED BED REACTOR (Peristaltic Pump Feed System)

More Views

RTD STUDIES IN PACKED BED REACTOR (Peristaltic Pump Feed System)

Code:
DESCRIPTION:
RTD Reactions:
Axial diffusion and dispersion of fluid in packed beds are important for design and operation of separation equipment and Chemicals reactors. The tracer technique, the most widely used method for the study of axial dispersion. In stimulus response experimentation, we perturb the system using pulse input of tracer and then see how the system reacts or responds to this stimulus. The analysis of the response gives the desired information about the system.
 
The setup consists of a glass column packed with Rasching Rings and one feed tank. Water is fed to the reactor through liquid distributor, fitted at the bottom of the column. Peristaltic Pump is provided to measure the flow of water. For understanding the R.T.D. characteristics, a special arrangement to inject tracer into the lower end of reactor, using a syringe, is provided. Samples can be taken periodically from the top outlet of reactor.
 
EXPERIMENTATION:
  1. To plot RTD curve for Packed Bed Reactor.
  2. To determine the Dispersion No. 
UTILITIES REQUIRED:
  • Water Supply.
  • Floor Drain.
  • Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted. 
TECHNICAL DETAILS:
Reactor Column Material Borosilicate Glass capacity 1.2 Ltrs(approx.)
Packing Rasching Rings, Material Borosilicate Glass.Size 8-10mm (approx)
Feed Tank Material Stainless Steel, Capacity - 20 Ltrs.
Piping Stainless Steel and PVC.
Flow Measurement Peristaltic Pumps, 1No. (for water).
Stop Watch Electronic
Special arrangement to inject tracer into the lower end of reactor
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No.
Description
JICRE-016C
RTD STUDIES IN PACKED BED REACTOR (Peristaltic Pump Feed System)
 
Description

Details

DESCRIPTION:
RTD Reactions:
Axial diffusion and dispersion of fluid in packed beds are important for design and operation of separation equipment and Chemicals reactors. The tracer technique, the most widely used method for the study of axial dispersion. In stimulus response experimentation, we perturb the system using pulse input of tracer and then see how the system reacts or responds to this stimulus. The analysis of the response gives the desired information about the system.
 
The setup consists of a glass column packed with Rasching Rings and one feed tank. Water is fed to the reactor through liquid distributor, fitted at the bottom of the column. Peristaltic Pump is provided to measure the flow of water. For understanding the R.T.D. characteristics, a special arrangement to inject tracer into the lower end of reactor, using a syringe, is provided. Samples can be taken periodically from the top outlet of reactor.
 
EXPERIMENTATION:
  1. To plot RTD curve for Packed Bed Reactor.
  2. To determine the Dispersion No. 
UTILITIES REQUIRED:
  • Water Supply.
  • Floor Drain.
  • Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted. 
TECHNICAL DETAILS:
Reactor Column Material Borosilicate Glass capacity 1.2 Ltrs(approx.)
Packing Rasching Rings, Material Borosilicate Glass.Size 8-10mm (approx)
Feed Tank Material Stainless Steel, Capacity - 20 Ltrs.
Piping Stainless Steel and PVC.
Flow Measurement Peristaltic Pumps, 1No. (for water).
Stop Watch Electronic
Special arrangement to inject tracer into the lower end of reactor
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No.
Description
JICRE-016C
RTD STUDIES IN PACKED BED REACTOR (Peristaltic Pump Feed System)
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282