The Split Air Conditioning Test Rig unit is required to conduct experiments and demonstrate the process of cooling of atmospheric air. The unit will be fitted with all instruments facilities so that temperature, pressure etc. may be measured at different points in the air conditioning system.
 
EXPERIMENTATION:
  •  To study the Vapour Compression air conditioning cycle.
  •  To Calculate Co-efficient of performance- (COP) by the use of P-H diagram. 
UTILITIES REQUIRED :
  •  Electric supply Single Phase, 220 V AC, 50 Hz., 10 Amp.
  •  Floor area : 2 m x 1m 
TECHNICAL DETAILS:
Compressor Hermitically sealed compressor.Capacity 1 Ton, Kirloskar make.
Condenser Air cooled compatible to compressor
Condenser Cooling Fan Compatible capacity with permanentlubricated motor.
Pressure Gauges 2 Nos.
Evaporator Made of copper tube and aluminumfins fitted with compatible capacity fan.
Expansion Device Capillary Tube Compatible capacity.
Safety Control overload and over current protectors for compressor and Time delay circuit.
Temperature Sensor RTD PT-100 Type.
Temperature Measurement  Digital Temperature Indicator with multi-channel switch.
All Other accessories like filter drier will be provided.
An ENGLISH instruction manual will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JRAC-003 SPLIT AIR CONDITIONING TEST RIG
 
Description

Details

 
DESCRIPTION :
The Split Air Conditioning Test Rig unit is required to conduct experiments and demonstrate the process of cooling of atmospheric air. The unit will be fitted with all instruments facilities so that temperature, pressure etc. may be measured at different points in the air conditioning system.
 
EXPERIMENTATION:
  •  To study the Vapour Compression air conditioning cycle.
  •  To Calculate Co-efficient of performance- (COP) by the use of P-H diagram. 
UTILITIES REQUIRED :
  •  Electric supply Single Phase, 220 V AC, 50 Hz., 10 Amp.
  •  Floor area : 2 m x 1m 
TECHNICAL DETAILS:
Compressor Hermitically sealed compressor.Capacity 1 Ton, Kirloskar make.
Condenser Air cooled compatible to compressor
Condenser Cooling Fan Compatible capacity with permanentlubricated motor.
Pressure Gauges 2 Nos.
Evaporator Made of copper tube and aluminumfins fitted with compatible capacity fan.
Expansion Device Capillary Tube Compatible capacity.
Safety Control overload and over current protectors for compressor and Time delay circuit.
Temperature Sensor RTD PT-100 Type.
Temperature Measurement  Digital Temperature Indicator with multi-channel switch.
All Other accessories like filter drier will be provided.
An ENGLISH instruction manual will be provided along with the Apparatus