jainsonsindia partners
 Enquiry Cart

STEFAN BOLTZMANN'S APPARATUS

More Views

STEFAN BOLTZMANN'S APPARATUS

Code:
DESCRIPTION:
The apparatus is designed to determine the Stefan Boltzmann constant. The apparatus consists of a hemisphere fixed to a Bakelite plate, the outer surface of which forms the jacket to heat it.

Hot water to heat the hemisphere is obtained form a hot water tank, which is fixed above the hemisphere. The copper test disc is introduced at the center of hemisphere. The temperatures of hemisphere and test disc are measured with the help of temperature sensors.

E
XPERIMENTATION:
  • Determination of Stefan Boltzmann constant and study the effect of hemisphere temperature on it.
UTILITIES REQUIRED:
  • Electricity Supply : 1 Phase, 220 V AC, 2 kW.
  • Table for set-up support. 
TECHNICAL DETAILS : 
Hemisphere Dia.- 200 mm (approx.) made of Copper
Jacket Dia. 250 mm (approx.) made of Stainless Steel
Test Disc Size 20 mm Dia. x 1.5-mm thickness made of Copper
Water Tank Stainless steel 12 Ltrs. cap.
Heater Nichrome wire immersion heater.
Control panel comprises of
Digital Temp. Controller 0 to 199.9°C, (for water tank)
Digital Temp. Indicator 0 to 199.9°C, with multi channel switch
Temp. Sensors RTD PT-100 type-2Nos.
Standard make On/Off switch, Mains Indicator etc.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will beprovided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIHT-072 STEFAN BOLTZMANN'S APPARATUS
 
Description

Details

DESCRIPTION:
The apparatus is designed to determine the Stefan Boltzmann constant. The apparatus consists of a hemisphere fixed to a Bakelite plate, the outer surface of which forms the jacket to heat it.

Hot water to heat the hemisphere is obtained form a hot water tank, which is fixed above the hemisphere. The copper test disc is introduced at the center of hemisphere. The temperatures of hemisphere and test disc are measured with the help of temperature sensors.

E
XPERIMENTATION:
  • Determination of Stefan Boltzmann constant and study the effect of hemisphere temperature on it.
UTILITIES REQUIRED:
  • Electricity Supply : 1 Phase, 220 V AC, 2 kW.
  • Table for set-up support. 
TECHNICAL DETAILS : 
Hemisphere Dia.- 200 mm (approx.) made of Copper
Jacket Dia. 250 mm (approx.) made of Stainless Steel
Test Disc Size 20 mm Dia. x 1.5-mm thickness made of Copper
Water Tank Stainless steel 12 Ltrs. cap.
Heater Nichrome wire immersion heater.
Control panel comprises of
Digital Temp. Controller 0 to 199.9°C, (for water tank)
Digital Temp. Indicator 0 to 199.9°C, with multi channel switch
Temp. Sensors RTD PT-100 type-2Nos.
Standard make On/Off switch, Mains Indicator etc.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will beprovided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIHT-072 STEFAN BOLTZMANN'S APPARATUS
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282