The set-up consists of different pressure measurement devices fitted in a pipe line, in which an Orifice is fitted to create the pressure difference. Present set-up is self-contained water re- circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line.
 
EXPERIMENTATION:
  • To demonstrate the working of different pressure measuring devices.
  • To measure the pressure and pressure difference by pressure gauge, single column manometer, U-Tube manometer & Inclined tube manometer.
 
UTILITIES REQUIRED:
  • Electricity Supply:             Single phase, 220 VAC, 50 Hz, 5-15 amp. combined socket with earth connection.
  • Water Supply (Initial fill)
  • Floor Drain required.
  • Floor Area Required: 1.5 m x 0.75 m
  • Mercury (Hg) for manometer (750 gm).
TECHNICAL DETAILS:
Single Well Manometer Single Tube Type.
Differential Manometer U Tube Type.
Sensitive Manometer. Inclined Tube Type
Pressure Gauge. Bourdon Type
Water Circulation FHP Pump, Champion make.
Sump Tank Capacity 60 Ltrs.
Control Panel 
Comprises of
Standard make On/Off Switch, Mains Indicator, etc.
Tanks will be made of Stainless Steel.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIHD-023 STUDY OF PRESSURE MEASUREMENT
 
Description

Details

DESCRIPTION:
The set-up consists of different pressure measurement devices fitted in a pipe line, in which an Orifice is fitted to create the pressure difference. Present set-up is self-contained water re- circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line.
 
EXPERIMENTATION:
  • To demonstrate the working of different pressure measuring devices.
  • To measure the pressure and pressure difference by pressure gauge, single column manometer, U-Tube manometer & Inclined tube manometer.
 
UTILITIES REQUIRED:
  • Electricity Supply:             Single phase, 220 VAC, 50 Hz, 5-15 amp. combined socket with earth connection.
  • Water Supply (Initial fill)
  • Floor Drain required.
  • Floor Area Required: 1.5 m x 0.75 m
  • Mercury (Hg) for manometer (750 gm).
TECHNICAL DETAILS:
Single Well Manometer Single Tube Type.
Differential Manometer U Tube Type.
Sensitive Manometer. Inclined Tube Type
Pressure Gauge. Bourdon Type
Water Circulation FHP Pump, Champion make.
Sump Tank Capacity 60 Ltrs.
Control Panel 
Comprises of
Standard make On/Off Switch, Mains Indicator, etc.
Tanks will be made of Stainless Steel.
An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.
 
Ordering Details:
Catalogue No Description
JIHD-023 STUDY OF PRESSURE MEASUREMENT
 
Additional Information

Additional Information

Code No
Reviews

Fatal error: Uncaught Exception: Warning: Unknown: write failed: Disk quota exceeded (122) in Unknown on line 0 in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php:282 Stack trace: #0 [internal function]: mageCoreErrorHandler(2, 'Unknown: write ...', 'Unknown', 0, NULL) #1 {main} thrown in /home2/jainsonsindia/public_html/app/code/core/Mage/Core/functions.php on line 282