- Description
-
Details
Temperature & Humidity Chambers
Wide temperature range down to -70 °C and high advanced safety features for quality and reliability
Control range
-
Temperature range from -70 to 150°C Humidity range from 25 to 95% RH
Performance
-
Microprocessor PID control / Temperature calibration / Automatic tuning.
-
Advanced performance of low and high temperature and humidity control, achieved by adapting the humidification tank exterior to the chamber, added benefit for long term test.
-
Water recycling and filtering system reduce water consump-tion for longer operation.
-
Air-tight door closure with perfect sealed packing.
- Heat-resistant silicone packing completely blocks high heat leakage from the inner chamber.
- Two-point door latch also enhances tightness to door closure.
-
Energy efficiency is achieved by optimization of the insulation system.
- Even if the unit is operating at max. temperature, the surface of the unit doesn’t allow high temperatures of over 60℃.
Safety
- Built in door lock with a key.
- Automatic shut off after overheat alarm.
- Low and empty water level alarm.
- Power supply leakage breaker.
- Over current protection.
- Open door alarm.
- Color LCD controller
- Computer interface
- Door handle
- Portable water container
Convenience
-
Three different volume sizes are available to suit any users’needs.
- Various volume sizes, available to suit any users’ need.
-
Corrosion resistance stainless steel chamber and electric polished humidification tank.
-
Maintenance of water supply are easily performed with a front water tank.
- Portable water container makes supplying water convenient.
-
Water supply during operation is also available for long term test purposes.
-
Direct water system provides user great convenience when performing long-term tests. (optional)
-
Clear observation of samples.
- Tempered glass door with built in heating wire.
- Energy efficient, long life span LED lighting.
- Wider view, inner glass door is available for monitoring of samples. (optional)
-
Cable port for introduction of external probes or wires.
- 50mm diameter cable port comes standard on the left side of the unit.
- Additional 50mm or 80mm diameter cable ports, custom ordered. (optional)
-
Casters for easy mobility during installation or relocation.
-
User friendly LCD controller.
- 5.7 inch colorful interactive touch type LCD controller.
- Set value and present value are clearly visible together on display.
- Operating progressvisible in graph mode allow for direct data interpretation.
- Built-in SD card drive.
- Trilingual support. (English / Chinese / Korean)
- Temperature and other operating parameters recorded with use of selectable recorder. (optional)
- Sufficient programmable control support.
Description No Programmable pattern capacity 120 Pattern repeat time 999 Max. segments per a pattern 100 Available max. segments* 1200 Programmable process time per a segment 0 to 999hr
59 min 59 sec-
* Even though the max. segments per a pattern are 100, available total segments are up to 1200 not 12000, so you need to arrange the number of segment an patterns properly.
-
Computer interface.
- RS-485 communication port enables connection of up to maximum 9 units. Simultaneous monitoring and operating of multiple units is an available feature.(optional)
- Program patterns are simple to set with the use of our software.
- Storage of program information, backup of value settings, recovery, temperature, humidity values.
- RS-232 communication port comes standard.
Model LSTH-KH-180 LSTH-KH-300 LSTH-KH-408 Chamber volume (L / cu ft) 189 / 7.4 302 / 11.9 408 / 14.4 Controller Programmable, Touch screen type controller (5.7” color monitor) Temperature Range (℃ / ℉) -70 to 150 / -94 to 302 without humidity, 15 to 90 / 59 to 194 with humidity* Best programmable control range : -60 to 140 / -76 to 284 Fluctuation 1) (±℃ / ℉) at 40℃ / 75%RH 0.3 / 0.54 Variation 1) (±℃ / ℉) at 40℃ / 75%RH 0.5 / 0.90 Time Heating - without humidity (min.) 70 from -70℃ to 120℃ (-96℉ to 248℉) Cooling - without humidity (min.) 80 from 20℃ to -70℃ (68℉ to -96℉) Humidity Range (%RH) 25 to 95
※ See Feature page for more detailed humidity range check.Fluctuation 1) (±%RH) at 75%RH / 40℃ 0.4 Variation 1) (±%RH) at 75%RH / 40℃ 3.0 Refrigeration System Mechanical dual stage refrigerator system (air-cooled condenser) Refrigerant R-507, R-23 Water supply Capacity 15L (0.53cu ft) - Cartridge type Water quality pH6.2 to 7.2 / Electrical conductivity 20㎲ /cm to below No. of wire shelves (standard / max.) 2 / 9 2 / 10 2 / 10 Distance of between shelves (mm / inch) 60 / 2.4 60 / 2.4 60 / 2.4 Max. load per shelf (kg / lbs) 20 / 44.1 25 / 55.1 25 / 55.1 Permitted total load (kg / lbs) 50 / 110.2 65 / 143.3 65 / 143.3 Dimension (W×D×H) Interior (mm / inch) 500×630×600 / 19.7×24.8×23.6 600×630×800 / 23.6×24.8×31.5 600×850×800 / 23.6×33.5×31.5 Exterior (mm / inch) 1050x1615x1560 / 41.3x63.6x61.4 1150x1615x1760 / 45.3x63.6x69.3 1150x1835x1760 / 45.3x72.2x69.3 Viewing windows (mm / inch) 200×330 / 7.9×13 Net weight (kg / lbs) 320 / 705.5 385 / 848.8 410 / 903.9 Cable port Basically one hole provided / Ø50mm (2”)- Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”) Interface port Basically RS-232C [RS-485-optional] Electrical requirements (380V, 50Hz) 3ph / 10.1A 3ph / 10.2A -
1) Technical data according to DIN 12880, IEC 60068.
-
※ Permissible environmental conditions: temperature (18 to 30℃) and relative humidity (up to 85%).
※ All specifications are under ambient temperature 20℃ (68℉), No load.
-