CONSTRUCTIONAL AND SALIENT FEATURES
  • Outer body made of CRC sheet duly powder coated.
  • Inner cylinder is made of heavy gauge welded Stainless Steel Sheet.
  • Lid is made of thick Stainless Steel plate.
  • Lid is closed through nut locking arrangement.
  • Working Pressure range upto 300 psi (21± 1kg/cm2).
  • Temperature range up to 215OC.
  • Highly accurate and reliable RTD (Pt-100) sensor for accurate temperature control.
  • User settable Digital Temperature Indicator cum Controller is fitted for automatic control with respect to time and temperature.
  • User settable in-built digital buzzer timer in minutes for automatic control of sterilization time.
  • Manual purging (exhaust of pressure) at cycle end, on sound of audio buzzer.
  • Fitted with safety valve as a safety device.
  • Fitted with vacuum breaker to break vacuum in case of formation of vacuum due to steam condensation.
  • Fitted with Automatic Pressure Control Switch for double safety, in case Digital Temperature Controller fails.
  • Provided with double safety valve protection.
  • Fitted with a reliable pressure gauge.
MODEL INNER DIMENSION (DIA X HT)
JUHPA-12 150 x 400mm
JUHPA-22 250 x 450 mm
Description

Details

Ultra High Pressure Autoclave
Vertical System For Testing Of Samples Under High Temperature & Pressure
CONSTRUCTIONAL AND SALIENT FEATURES
  • Outer body made of CRC sheet duly powder coated.
  • Inner cylinder is made of heavy gauge welded Stainless Steel Sheet.
  • Lid is made of thick Stainless Steel plate.
  • Lid is closed through nut locking arrangement.
  • Working Pressure range upto 300 psi (21± 1kg/cm2).
  • Temperature range up to 215OC.
  • Highly accurate and reliable RTD (Pt-100) sensor for accurate temperature control.
  • User settable Digital Temperature Indicator cum Controller is fitted for automatic control with respect to time and temperature.
  • User settable in-built digital buzzer timer in minutes for automatic control of sterilization time.
  • Manual purging (exhaust of pressure) at cycle end, on sound of audio buzzer.
  • Fitted with safety valve as a safety device.
  • Fitted with vacuum breaker to break vacuum in case of formation of vacuum due to steam condensation.
  • Fitted with Automatic Pressure Control Switch for double safety, in case Digital Temperature Controller fails.
  • Provided with double safety valve protection.
  • Fitted with a reliable pressure gauge.
MODEL INNER DIMENSION (DIA X HT)
JUHPA-12 150 x 400mm
JUHPA-22 250 x 450 mm