Sath Type Leakage Detection Sterilizer
This series high temperature pulsation vacuum sterilizer applies deionised water as its sterilization medium. With the internal high temperature deionised water circulation, it realizes sterilization by evenly spraying the processed deionised water onto items to be sterilized for a period. With a wide temperature range and uniformity, this equipment has successfully prevented the secondary pollution during the procedure. It ensures the scrap rate up to 100% by implementing means of vacuum and colour leakage detection methods. Applicable for equipment and devices requiring high temperature sterilization, leakage detection and cleaning processing for injection and oral liquid products contained in ampoule, vials and tube-type bottles. It has been widely used in pharmaceutical, medical, and scientific research projects.
Main Parameters and Utilities
| Design Pressure |
0.245 MPa |
| Design Temperature |
1390 C |
| Vacuum |
-0.09 MPa |
| Water Source Pressure |
0.15-0.3 MPa |
| Steam Pressure |
0.3-0.7 MPa |
| Working Pressure |
0.225 MPa |
| Working Temperature |
80-1340C |
| Temperature Equilibrium |
≤± 10C |
| Compressed Air Pressure |
0.3-0.7 MPa |
| Power |
AC 380V; 50 Hz |
Specifications & Ordering Details
| Catalogue No |
Overall Size
L x W x H (mm)
|
Chamber Size
L x W x H (mm)
|
Steam Consumption (Kg) |
Consumption Of
Cleaning Water (KG)
|
Consumption Of
Deionised Water (KG)
|
Sterilization Vehicle |
Net Weight (KG) |
| JWG-SS12 |
1750 X 1650 X 1950 |
1450 X 680 X 1180 |
85 |
760 |
140 |
2 |
1750 |
| JWG-SS15 |
2150 X 1650 X 1950 |
1850 X 680 X 1180 |
100 |
1000 |
170 |
2 |
2000 |
| JWG-SS20 |
1950 X 2000 X 2200 |
1600 X 900 X 1400 |
140 |
1250 |
220 |
2 |
2750 |
| JWG-SS25 |
2300 X 2000 X 2200 |
1950 X 900 X 1400 |
180 |
1500 |
260 |
2 |
3150 |
| JWG-SS30 |
2750 X 2000 X 2200 |
2400 X 900 X 1400 |
240 |
1800 |
300 |
3 |
3550 |
| JWG-SS40 |
3550 X 2000 X 2200 |
3200 X 900 X 1400 |
300 |
2100 |
420 |
3 |
4050 |
Structure and Characteristic of The Equipment
Body of the sterilizer:
-
It is designed and manufactured in accordance with GB150 "the Pressure Vessel", and TSG R0004-2009 Safety and Technology Specification for Fixed Monitor Vessels and related inspection procedures.
-
Tank of the horizontal rectangular double-deck structure is made from S30408.
-
Door sealing: Pneumatic sealing; both doors are interlocked and completely conform to the requirements of the specification.
-
The equipment has standard GMP authentication interface.
Sterilizer piping system:
The pipeline is designed with the best configuration. By employing imported parts and quality domestic brands into main components, this system presents online sterilization option.
Sterilizer control system:
with the adoption of Siemens PLC plus Siemens touch screen, this system is easy to implement the program selection, parameter setting, equipment operation, report processing and other functions. It has perfect safety measures. The F0 value and the temperature time give double guarantee for sterilization. A single parameter control is also available. It has a perfect sterilization records.
Load Capacity of The Equipment
| Catalogue No |
1 ml |
2 ml |
5 ml |
10 ml |
20 ml |
| JWG-SS12 |
103008 |
71808 |
29808 |
17360 |
10608 |
| JWG-SS15 |
133632 |
92048 |
38880 |
22568 |
13014 |
| JWG-SS20 |
184704 |
123760 |
48576 |
33600 |
19008 |
| JWG-SS25 |
255744 |
169344 |
66792 |
45600 |
25344 |
| JWG-SS30 |
291264 |
196560 |
78936 |
52800 |
30144 |
| JWG-SS40 |
415584 |
278640 |
109296 |
75600 |
40464 |